Development of a standardized and validated flow cytometry approach for monitoring of innate myeloid immune cells in human blood
He QS; Diks AM; Hernandez-Delgado A; de Bruin-Versteeg S; van Gaans-van den Brink JAM; Berbers GAM; Versteegen P; Naber BAE; Orfao A; van Dongen JJM; Kassem S; van der Pan K; Groenland RJ; Almeida J; de Bie FJ; Khatri I; Diez P; de Jager AL; de Laat IF; de Mooij B; van den Bossche WBL; Damasceno D; Teodosio C; van der Sluijs-Gelling AJ; Berkowska MA; Louis A; Barkoff AM; Ferwerda G
Development of a standardized and validated flow cytometry approach for monitoring of innate myeloid immune cells in human blood
He QS
Diks AM
Hernandez-Delgado A
de Bruin-Versteeg S
van Gaans-van den Brink JAM
Berbers GAM
Versteegen P
Naber BAE
Orfao A
van Dongen JJM
Kassem S
van der Pan K
Groenland RJ
Almeida J
de Bie FJ
Khatri I
Diez P
de Jager AL
de Laat IF
de Mooij B
van den Bossche WBL
Damasceno D
Teodosio C
van der Sluijs-Gelling AJ
Berkowska MA
Louis A
Barkoff AM
Ferwerda G
FRONTIERS MEDIA SA
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2022112968018
https://urn.fi/URN:NBN:fi-fe2022112968018
Tiivistelmä
Innate myeloid cell (IMC) populations form an essential part of innate immunity. Flow cytometric (FCM) monitoring of IMCs in peripheral blood (PB) has great clinical potential for disease monitoring due to their role in maintenance of tissue homeostasis and ability to sense micro-environmental changes, such as inflammatory processes and tissue damage. However, the lack of standardized and validated approaches has hampered broad clinical implementation. For accurate identification and separation of IMC populations, 62 antibodies against 44 different proteins were evaluated. In multiple rounds of EuroFlow-based design-testing-evaluation-redesign, finally 16 antibodies were selected for their non-redundancy and separation power. Accordingly, two antibody combinations were designed for fast, sensitive, and reproducible FCM monitoring of IMC populations in PB in clinical settings (11-color; 13 antibodies) and translational research (14-color; 16 antibodies). Performance of pre-analytical and analytical variables among different instruments, together with optimized post-analytical data analysis and reference values were assessed. Overall, 265 blood samples were used for design and validation of the antibody combinations and in vitro functional assays, as well as for assessing the impact of sample preparation procedures and conditions. The two (11- and 14-color) antibody combinations allowed for robust and sensitive detection of 19 and 23 IMC populations, respectively. Highly reproducible identification and enumeration of IMC populations was achieved, independently of anticoagulant, type of FCM instrument and center, particularly when database/software-guided automated (vs. manual "expert-based") gating was used. Whereas no significant changes were observed in identification of IMC populations for up to 24h delayed sample processing, a significant impact was observed in their absolute counts after >12h delay. Therefore, accurate identification and quantitation of IMC populations requires sample processing on the same day. Significantly different counts were observed in PB for multiple IMC populations according to age and sex. Consequently, PB samples from 116 healthy donors (8-69 years) were used for collecting age and sex related reference values for all IMC populations. In summary, the two antibody combinations and FCM approach allow for rapid, standardized, automated and reproducible identification of 19 and 23 IMC populations in PB, suited for monitoring of innate immune responses in clinical and translational research settings.
Kokoelmat
- Rinnakkaistallenteet [19207]